• PC Material GFCI Double Universal Socket with Grounding
  • PC Material GFCI Double Universal Socket with Grounding
  • PC Material GFCI Double Universal Socket with Grounding
  • PC Material GFCI Double Universal Socket with Grounding

PC Material GFCI Double Universal Socket with Grounding

Grounding: Standard Grounding
Type: Microwave Sensor Switch
Rated Current: 16A
Shell Material: Flame Retardant PC Plastic
Application: Commercial, Residential/General-Purpose
Function: Leakage Protection Socket
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory, Individuals/SOHO
Gold Member Since 2024

Suppliers with verified business licenses

Zhejiang, China
to see all verified strength labels (25)

Basic Info.

Model NO.
WB932
IP Rating
IP20
Brand
Lide
Certification
CE, ISO
Number of Holes
Porous
Plastic Body
Brass Inside
Material
PC Material
MOQ
1000PCS/Item for Switch Socket, 1000PCS/Item for T
Service
OEM ODM Is Accepted
Principle
Infrared
Wires
Two-Wires
Standard
Standard
Rated Power (Pn)
3500W
Rated Frequency (Fn)
50Hz/60Hz
Mechanical and Electrical Life
6000 Times
Transport Package
Poly Bag
Specification
16A 250V
Trademark
LIDE
Origin
Wenzhou China
HS Code
85365000
Production Capacity
10000000PCS/Year

Product Description

PC material GFCI Double universal socket with grounding
Product Characteristic
The switch contacts are made of high quality silver alloy material,which have a good performance against electric arc and melt weld.The on-off operations exceed 40000 times.
The socket are made of phosphor bronze, which have the character of good electrical conductivity and lasting elasticity.
Outline size: 80x80, 86x86mm
Installation size: 60
Material: PC POM PA66
Copper: QSn5.6-0.1 H62 Hpb59

Switch Specification
Lifetime ≥40000
Heat-resistant 100  C / 1h
Insulation Resistance ≥5M Ω
Damp Resistance 48h > 5M Ω
Temperature Raise ≤ 45K
Earthing Provision ≤0.05M Ω

Socket Specification
Lifetime ≥5000
Heat-resistant 100  C / 1h
Insulation Resistance ≥5M Ω
Damp Resistance 48h > 5M Ω
Temperature Raise ≤ 45K
Earthing Provision ≤0.05M Ω
Electric Strength 2000 V ~1 min
PC Material GFCI Double Universal Socket with Grounding

Installation Manual 

For your personal safety, please read the instructions carefully when installing and using this product, to bring convenience for your life!

1.Product Features

   This product is electrical leakage protection , installed on a single-phase power supply 250V / 50Hz line to prevent electric shock, it can automatically disconnect power sources within 0.1 seconds to prevent fatal causing bodily harm protected contacts, when the electrical load to ground is more than 10 mA leakage current,(The harm caused by touching the poles at the same time can not be protected); Meanwhile the product also has anti-lightning and anti-surge interference function, to ensure the normal operation of electrical appliances and equipment, this product is used insulated flame retardant PC material, with superior fire-retardant features.

    Apply to electric water heaters, refrigerators, washing machines, kettles, hair dryer and other household appliances and hand-held power tools, it is the safety power for household, commercial and other similar place.

2.The main technical parameters

   (1). Basic parameters

         Rated voltage (Un):250VAC

         Rated current (In):16A

         Rated power (Pn):3500W

         Rated frequency (Fn):50Hz/60Hz

         Mechanical and electrical life: 6000 times

   (2). Leakage protection operation characteristics:

         Rated operation (leakage) currents:10-15mA

         Rated leakage current breaking time:≤0.1s

3.Product Installation

  (1) Before installing the wire, make sure the power is off, after the installation to ensure proper installation, it would be tested for continuity.

  (2) 2 to 3 mm diameter copper wire, 1.6cm joint with striping the insulation sheathing, inserted at the terminals with a  tool reliable fastened;

  (3) power supply line L can be connected to the product's power cord terminals;

  (4) Neutral line N can be connected to product's neutral terminal;

  (5) Ground line can be connected to product's ground terminal

  (6) Load terminals can be connected directly to the load, or be connected to the other common socket, the connected socket at the same time with leakage protection function.

Note: If the Live line and the neutral line reversed, power indicator light can not be extinguished after the leakage protection.

4.Test

 The product can be tested after confirming wiring and installation are correct. Test procedures are as follows:

 (1) Sockets access voltmeter or lamps and other loading.

 (2) Turn off the power switch, the power indicator light is on;

 (3) Press the RESET button, connect to the load, Voltmeter displayed correctly or light is on;

 (4) Press the TEST button, disconnected to the load, Voltmeter doesn't display or lights is off and meanwhile the power indicator light is off;

(5) Monthly, press the TEST button to test the product works properly or not and then press the RESET to restart.


About us
Company name: Zhejiang Lide Electric Co.,Ltd
Founding Year: 1997
Qty of employee: 800 employees
Production Capacity: 6000000pcs month
With 46 set injection machines,part of them with Robert.Operate fully automatically. 25
pcs fully automatically assembly line.
Factory In Wenzhou
4000sq meter production Area
7000 sq.meter storage Area

Facotry in Qidong
52000sq. meter land Area
30000sq.meter Building Area

Main products: Electrical equipments. Specilizes in Wall switch and socket,circuit breaker, exhaust fan,mould
Qualifications of Quality: CE CB BS SASO SAA ISO9001

PC Material GFCI Double Universal Socket with Grounding
PC Material GFCI Double Universal Socket with Grounding


PC Material GFCI Double Universal Socket with Grounding






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now